Type: General-purpose compact limit switch
Make: Azbil (Yamatake)
Model: 5LS1-JEC
Actuator: Roller plunger / optional lever types
Contacts: 2-circuit double-break basic switch
Output Rating: Up to ~10 A (silver contacts) / ~1 A (gold-plated) (standard 45–65 Hz & DC)
Protection: IP67 (oil/water/dust-resistant rugged die-cast housing)
Certifications: UL / CSA / CE / CCC certified
Indicators: LED / neon options available on specific sub-models
Application: Position/limit detection in industrial automation and machinery control
Type: General-purpose compact limit switch
Make: Azbil (Yamatake)
Model: 5LS1-JH
Actuator: Roller plunger style
Contacts: SPDT double-break basic switch
Operating Force: ~26.7 N (roller plunger)
Protection: IP67 (dust/water-resistant rugged housing)
Construction: Rugged die-cast aluminum case
Certifications: UL/CSA/CE/CCC options available
Application: Position/limit detection in industrial machinery control
Type: General-purpose compact limit switch
Make: Azbil (Yamatake)
Model: 5LS1-JSEC
Actuator: Roller plunger with boot seal (splash/oil resistant)
Contacts: Double-break basic switch (2 circuits)
Protection: IP67 (dust/water/oil resistant) rugged die-cast housing
Output Rating: Typically 10 A (silver) / 1 A (gold-plated) (AC/DC)
Certifications: UL / CSA / CE / CCC approved
Indicator: LED status indicator on some variants
Application: Position/limit detection in industrial machinery and automation systems
Type: General-purpose compact limit switch
Make: Azbil (Yamatake)
Model: 5LS7-JS
Actuator Type: Roller plunger / lever options (varies by sub-model)
Contacts: Double-break basic switch (robust contact design)
Protection: IP67 (dust/water-resistant rugged housing)
Housing: Die-cast aluminum body for industrial durability
Certifications: UL / CSA / CE / CCC approved
Electrical Rating: Up to ~10 A (silver contacts) / 1 A (gold-plated) at 240 Vac / 30 Vdc typical
Application: Position/limit detection in industrial machinery and automation
Type: General-purpose compact limit switch
Make: Azbil (Yamatake)
Model: 5LS7-JWC
Actuator: Boot-seal roller plunger / lever (spatter-guarded) option available
Contacts: Double-break basic switch (normal + changeover)
Protection: IP67 (dust/water/oil resistant) rugged die-cast housing
Rated Voltage: ~12–125 Vac/dc (common AC/DC operating range)
Current Rating: Up to ~10 A (silver contacts) / ~0.8–1 A (at 125 Vdc) typical
Indicators: LED lamp for status (many JWC variants)
Application: Limit/position detection in industrial automation and machinery control
Type: Microprocessor-based PID Temperature Controller
Size: 48 × 48 mm (1/16 DIN) panel mount
Power Supply: 100–240 VAC
Inputs: Universal (Thermocouple, RTD, Linear signals)
Outputs:
2 × Relay (3A, 250V)
1 × Analog Output (0–10V or 0/4–20mA)
Control Mode: ON/OFF
Display: Dual-line LED, Multi-line
IP Rating: IP65 (front panel)
Operating Temperature: 0°C to +50°C
Temperature Range: Up to +1750°C (depending on input type)
Communication: None (No serial communication in this variant)
Additional Features:
Auto-tuning
Self-tuning
Ramp/Soak
Alarm functions
Auxiliary input for Current Transformer (CT) (50mA AC)
Heater break or probe short-circuit alarm
Series: Gefran 600 PID Controller, 1/16 DIN (48×48 mm)
Supply: 100–240 VAC
Input: Universal (Thermocouple, RTD, Linear)
Output: Relay / Logic + Analog (0/4–20 mA, 0–10 V)
Alarms: 3 configurable (heater break, probe short, hot/cold, etc.)
Accuracy: ±0.2% FS
Display: Dual 4-digit LED (PV + SP), status indicators
Protection: IP65 front panel
Comm.: RS-485, Modbus-RTU (optional)
Size: 48×48 mm, depth ~99 mm
Size: 48×48 mm (1/16 DIN) panel mount
Power Supply: 100–240 VAC
Inputs: Universal (TC, RTD, mV, mA, V) + Aux CT input
Outputs: 2 Relay + 1 Analog (0–10V / 0/4–20mA)
Communication: None (No comms port in this version)
Display: Dual line LED, keypad control
Mounting: Panel mount, compact design
ype: PID Temperature / Process Controller
Size: 48 × 48 mm (1/16 DIN)
Mounting: Panel mount
Power Supply: 100–240 VAC
Inputs: Universal (Thermocouple, RTD, Linear signals)
Outputs:
2 × Relay (3A, 250V)
1 × Analog Output (Voltage or Current)
Control Mode: ON/OFF
Display: LED, Multi-line
Protection: IP65 (front panel)
Operating Temperature: 0°C to +50°C
Temperature Range: Up to +1750°C (depending on input type)
Communication: None (No serial communication in this variant)
Additional Features:
Auto-tuning
Self-tuning
Ramp/Soak
Alarm functions
Auxiliary input for Current Transformer (CT) (50mA AC)
Heater break or probe short-circuit alarm
Type: Advanced ultraviolet burner/flame controller
Make: Azbil (Yamatake)
Model: AUR300C122D0
Function: UV flame safeguard controller with dynamic self-checking for combustion safety systems. It continuously checks both its own circuitry and the connected UV flame detector to ensure reliable flame detection and safety shutdown on flame loss/fault.
Used With: UV flame detectors such as AUD300C / AUD500C (for oil/gas burner flame monitoring).
Features: LED status indicators (e.g., POWER, SHUTTER, START CHECK, FLAME) and output relays for flame status and safety interlocks; flame signal output (0–5 V) useful for monitoring/adjustment.
Safety: Does not include an ignition function—ignition must be handled by the burner system instrumentation with safety considerations.
Application: Combustion safety control on industrial oil/gas burners (continuous and batch operation)
Type: Advanced Ultraviolet Burner Controller
Make: Azbil (Yamatake)
Model: AUR300C13100
Function: Monitors flame signal from a UV flame detector and controls burner safety
Used With: UV flame detector such as AUD300C series to detect flame on oil/gas burners
Safety Features: Dynamic self-checking of both flame detector and controller to ensure reliable combustion safety control
Outputs: Relay outputs for flame status and safety interlocks
Application: Combustion safety control for industrial oil/gas burners (continuous and batch operation)
Type: Advanced ultraviolet burner/flame controller
Make: Azbil (Yamatake)
Model: AUR350C13100
Function: UV flame safeguard controller for combustion safety systems — monitors burner flame and shuts down on flame failure or fault.
Used With: Works with UV flame detectors like AUD300C/AUD500C for reliable flame detection.
Features: Dynamic self-checking of flame detection and controller circuits for safe operation.
Outputs: Relay outputs for flame status and safety interlocks; standard flame signal output (0–5 V DC) for monitoring/adjustment.
Communication: RS-485 interface (for PC/PLC monitoring and configuration).
Application: Combustion safety control in industrial oil/gas burners (continuous & batch operation)
WhatsApp us