Power supply: Probably 100-240 VAC, possibly also version(s) with 24 V supply depending on the code “IVM70
Input types: Supports thermocouple / RTD / DC signals (4-20 mA or 1-5 V) depending on configuration.
Output / Control modes: Single or dual outputs (relay / SSR / SSC / analog retransmission) with PID control, auto-tuning, possibly fuzzy/self-tuning variants.
Alarms & extras: Several programmable alarms, possibly heater burnout alarm; timer / ramp-soak profiling (up to 16 segments when two 8-segment profiles are linked) might be supported.
Front panel / protection: Large LED display; waterproof / weather-resistant faceplate (IP66 / NEMA-4X equivalent).
Display / Face: Large LED display, waterproof front panel (IP66 / NEMA-4X)
Input Types: Thermocouple / RTD; analog signals like 4-20 mA or 0-5 V
Control Outputs: Single or dual output options — relay, SSR/SSC type, possibly analog output for control or retransmission
Control Modes: PID, with auto-tuning plus fuzzy or self-tuning capability; ON/OFF control also supported Ramp/Soak Capability: Supports multi-step ramp/soak programs, typically 8 segments or linking to get up to 16 steps
Alarm / Extra Functions: Heater burnout alarm; programmable alarms; digital input for remote functions (e.g. remote setpoint, alarm reset etc.)
Power Supply: Likely universal; supports 100-240 VAC and possibly lower supply versions depending on the variant.